Euro America Windows

SlimWall 35

Technical information

Performance

Insulation

Thermal insulation (Best) – Uf

Thermal insulation – Uw

0.71 W/m²K

Ug 0.7W/m²K, warm edge spacer, @1.2×2.5m, 52mm glass

Thermal insulation – Ucw

0.8 W/m²K

Comfort

Air tightness

AE 1200 (1200Pa)

Wind load resistance

Class A5 (2000Pa)

Water tightness

RE1200 (1200 Pa)

Safety & Security

Burglar resistance

RC2

Impact resistance

I5E5

* Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative.

Properties

Max. dimensions & weight

Max. weight of glass

450 kg

Max. intertia transom – Ix

1200 mm

Min. intertia mullion – Ix

76.961 cm4

Min. intertia transom – Iy (glass load)

200 kg

Max. intertia mullion – Ix

572.545 cm4

Max. intertia transom – Iy (glass load)

800 kg

Min. intertia transom – Ix

70.5 cm4

Sightlines

Min. width transom profile

35 mm

Max. depth mullion

194 mm

Min. vent width (inward opening)

35 mm

Min. depth transom

88.5 mm

Min. visible width (exterior view)

35 mm

Max. depth transom

193.5 mm

Min. frame width (outward opening)

89 mm

Glazing

Rebate height

10 mm

Min. glass thickness – vent

24 mm

Glazing method

Dry glazingSiliconized glazingExternal glazingPressure plate glazingFixed Glazing

Max. glass thickness – vent

57 mm