MasterLine 8
Technical information
Performance
Insulation
Thermal insulation (Best) – Uf
Thermal insulation – Uw
1.0 W/m²K
0.8 W/m²K
Uw Dependencies
Frame-vent: Ug 0.6W/m²K, warm edge spacer, @1.23×1.48m (104mm sight line), 36mm glass
Comfort
Air tightness
Class 4 (600Pa)
Acoustics – Rw(C;Ctr)
TUTI: 46(0;-3) dB DC: 44(-2;-4) dB
Water tightness
Class E900 (900Pa)
Durability
Class 3 (20000 cycles)
Wind load resistance
Class C4 (1600Pa)
Safety & Security
Burglar resistance
RC2,RC3,PAS 24
Fire resistance
EI 30, EI₁ 30, EI₂ 30, EW 30
Impact resistance
I5–E5
* Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative.
Properties
Max. dimensions & weight
Min. height of vent
600 mm
Max. width of vent
1700 mm
Max. height of vent
2800 mm
Max. width of vent
300 kg
Min. width of vent
450 mm
Max. weight of glass
1200 kg
Sightlines
Min. frame width (inward opening)
53 mm
Min. frame-vent width (outward opening)
138 mm
Min. vent width (inward opening)
37 mm
Min. width transom profile
55 mm
Min. frame-vent width (inward opening)
97 mm
Depth frame
77 mm
Min. frame width (outward opening)
20 mm
Depth Vent
87 mm
Min. vent width (outward opening)
118 mm
Depth frame-vent
87 mm
Glazing
Rebate height
27 mm
Max. glass thickness – frame/element
62 mm
Glazing method
Dry glazing–Siliconized glazing–Internal glazing–Glazing bead
Min. glass thickness – vent
Max. glass thickness – vent
13 mm
72 mm
Min. glass thickness – frame/element
4 mm