Euro America Windows

MasterLine 10

Technical information

Performance

Insulation

Thermal insulation (Best) – Uf

Thermal insulation – Uw

0.99 W/m²K

0.8 W/m²K

Uw Dependencies

Frame-vent: Ug 0.6W/m²K, warm edge spacer, @1.23×1.48m (104mm sight line), 48mm glass

Comfort

Air tightness

Class 4 (600Pa)

Acoustics – Rw(C;Ctr)

TuTi: 46(-1;-4) dB DC: 44(-2;-4) dB

Water tightness

Class E900 (900Pa)

Durability

Class 3 (20000 cycles)

Wind load resistance

Class C4 (1600Pa)

Safety & Security

Burglar resistance

RC2,RC3

* Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative.

Properties

Max. dimensions & weight

Min. height of vent

600 mm

Max. width of vent

1200 mm

Max. height of vent

2800 mm

Max. width of vent

200 kg

Min. width of vent

550 mm

Max. weight of glass

800 kg

Sightlines

Min. frame width (inward opening)

60 mm

Min. frame-vent width (outward opening)

140 mm

Min. vent width (inward opening)

37 mm

Min. width transom profile

87 mm

Min. frame-vent width (inward opening)

104 mm

Depth frame

97 mm

Min. frame width (outward opening)

27 mm

Depth Vent

107 mm

Min. vent width (outward opening)

113 mm

Depth frame-vent

107 mm

Glazing

Rebate height

27 mm

Max. glass thickness – frame/element

78 mm

Glazing method

Dry glazingSiliconized glazingInternal glazingGlazing bead

Min. glass thickness – vent

Max. glass thickness – vent

107 mm

88 mm

Min. glass thickness – frame/element

20 mm

Depth frame-vent

107 mm

Scroll to Top