EuroGuard Fire-Rated
Technical information
Performance
Insulation
Thermal insulation (Best) – Uf
Thermal insulation – Uw
2.4 W/m²K
1.5 W/m²K
Uw Dependencies
Frame-vent: Ug 1.0W/m²K, warm edge spacer, @1.23×1.48m (115mm sight line), 24mm glass
Comfort
Air tightness
Class 4 (600Pa)
Acoustics – Rw(C;Ctr)
42(-2;-4) dB
Water tightness
Class E750 (750Pa)
Durability
Class 2 (10000 cycles)
Wind load resistance
Class C4 (1600Pa)
Safety & Security
Burglar resistance
PAS 24 – RC2 – RC3
Fire resistance
EI₂ 30 – EW 30
* Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative.
Properties
Max. dimensions & weight
Max. surface of vent
2.16 m2
Sightlines
Min. frame width (inward opening)
77 mm
Depth frame
68 mm
Min. vent width (inward opening)
0 mm
Depth Vent
77 mm
Min. frame-vent width (inward opening)
77 mm
Depth frame-vent
77 mm
Min. width transom profile
76 mm
Glazing
Rebate height
25 mm
Min. glass thickness – vent
15 mm
Glazing method
Dry glazing–Internal glazing–Glazing bead
Max. glass thickness – vent
52 mm