Euro America Windows

ConceptSystem 77

Technical information

Performance

Insulation

Thermal insulation (Best) – Uf

Uw Dependencies

1.8 W/m²K

Single inward opening door: Ug 1.0W/m²K, warm edge spacer, @1.23×2.18m, 36mm glass

Thermal insulation – Ud

1.4 W/m²K

Comfort

Air tightness

Class 4 (600Pa)

Acoustics – Rw(C;Ctr)

42(-1;-4) dB

Water tightness

Class 7A (300Pa)

Durability

Class 8 (1000000 cycles)

Wind load resistance

Class C2 (800Pa)

Safety & Security

Burglar resistance

RC2,RC3,PAS 24

Fire resistance

EI₁ 30, EI₂ 30, EI₁ 60, EI₂ 60, EW 30

Impact resistance

I5E5

Bullet resistance

FB4FSGFB6Kalashnikov

* Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative.

Properties

Max. dimensions & weight

Min. height of vent

3000 mm

Max. width of vent

250 kg

Max. height of vent

500 mm

Max. weight of fixed vent

280 kg

Min. width of vent

1400 mm

Sightlines

Min. frame width (inward opening)

68 mm

Min. width transom profile

76 mm

Min. vent width (inward opening)

76 mm

Min. height threshold

0 mm

Min. frame-vent width (inward opening)

150 mm

Depth frame

68 mm

Min. frame width (outward opening)

42 mm

Depth Vent

68 mm

Min. vent width (outward opening)

102 mm

Depth frame-vent

68 mm

Min. vent width (outward opening)

150 mm

Glazing

Rebate height

25 mm

Max. glass thickness – frame/element

52 mm

Glazing method

Dry glazingSiliconized glazingInternal glazingGlazing bead

Min. glass thickness – vent

Max. glass thickness – vent

4 mm

52 mm

Min. glass thickness – frame/element

4 mm

Scroll to Top