ConceptWall 86
Technical information
Performance
Insulation
Thermal insulation (Best) – Uf
1.9 W/m²K
Comfort
Air tightness
AE 900 (900Pa)
Wind load resistance
Class B5 (2000Pa)
Water tightness
RE1200 (1200 Pa)
Acoustics – Rw(C;Ctr)
41(-2;-6) dB
Safety & Security
Burglar resistance
RC2
Impact resistance
I5–E5
* Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative.
Properties
Max. dimensions & weight
Min. height of vent
500 mm
Min. intertia mullion – Ix
13.85 cm4
Max. height of vent
2000 mm
Max. intertia mullion – Ix
544.25 cm4
Min. width of vent
500 mm
Min. intertia transom – Ix
38.86 cm4
Max. width of vent
2000 kg
Max. intertia transom – Ix
435.83 cm4
Max. weight of vent
180 kg
Min. intertia transom – Iy (glass load)
51.54 cm4
Max. weight of glass
300 kg
Max. intertia transom – Iy (glass load)
153.38 cm4
Sightlines
Min. width transom profile
86 mm
Max. depth mullion
120 mm
Min. visible width (interior view)
86 mm
Min. depth transom
26.8 mm
Min. visible width (interior view)
86 mm
Max. depth transom
144.5 mm
Min. visible width (exterior view)
6.5 mm
Min. depth mullion
73 mm
Glazing
Glazing method
Dry glazing–External glazing–Glazing bead–Structural Glued Glazing
Max. glass thickness – vent
38 mm