MasterLine 10
Technical information
Performance
Insulation
Thermal insulation (Best) – Uf
Thermal insulation – Uw
0.96 W/m²K
Single inward opening door: Ug 0.6W/m²K, warm edge spacer, @1.23×2.18m, 48mm glass
Thermal insulation – Ud
0.81 W/m²K
Comfort
Air tightness
Class 4 (600Pa)
Acoustics – Rw(C;Ctr)
40 (-1;-5) dB
Water tightness
Class 9A (600Pa)
Durability
Class 8 (1000000 cycles)
Wind load resistance
Class C3 (1200Pa)
Safety & Security
Burglar resistance
RC2
* Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative.
Properties
Max. dimensions & weight
Min. height of vent
3000 mm
Max. width of vent
250 kg
Max. height of vent
500 mm
Max. weight of glass
1200 kg
Min. width of vent
1400 mm
Sightlines
Min. frame width (inward opening)
83.5 mm
Min. width transom profile
87 mm
Min. vent width (inward opening)
71.5 mm
Min. height threshold
0 mm
Min. frame-vent width (inward opening)
162 mm
Depth frame
97 mm
Min. frame width (outward opening)
27 mm
Depth Vent
97 mm
Min. vent width (outward opening)
110.5 mm
Depth frame-vent
97 mm
Min. frame-vent width (outward opening)
162 mm
Max. depth transom
97 mm
Glazing
Rebate height
27 mm
Max. glass thickness – frame/element
78 mm
Glazing method
Dry glazing–Siliconized glazing–Internal glazing–Glazing bead
Min. glass thickness – vent
Max. glass thickness – vent
20 mm
78 mm
Min. glass thickness – frame/element
20 mm