MasterLine 10
Technical information
Performance
Insulation
Thermal insulation (Best) – Uf
Thermal insulation – Uw
0.99 W/m²K
0.8 W/m²K
Uw Dependencies
Frame-vent: Ug 0.6W/m²K, warm edge spacer, @1.23×1.48m (104mm sight line), 48mm glass
Comfort
Air tightness
Class 4 (600Pa)
Acoustics – Rw(C;Ctr)
TuTi: 46(-1;-4) dB DC: 44(-2;-4) dB
Water tightness
Class E900 (900Pa)
Durability
Class 3 (20000 cycles)
Wind load resistance
Class C4 (1600Pa)
Safety & Security
Burglar resistance
RC2,RC3
* Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative.
Properties
Max. dimensions & weight
Min. height of vent
600 mm
Max. width of vent
1200 mm
Max. height of vent
2800 mm
Max. width of vent
200 kg
Min. width of vent
550 mm
Max. weight of glass
800 kg
Sightlines
Min. frame width (inward opening)
60 mm
Min. frame-vent width (outward opening)
140 mm
Min. vent width (inward opening)
37 mm
Min. width transom profile
87 mm
Min. frame-vent width (inward opening)
104 mm
Depth frame
97 mm
Min. frame width (outward opening)
27 mm
Depth Vent
107 mm
Min. vent width (outward opening)
113 mm
Depth frame-vent
107 mm
Glazing
Rebate height
27 mm
Max. glass thickness – frame/element
78 mm
Glazing method
Dry glazing–Siliconized glazing–Internal glazing–Glazing bead
Min. glass thickness – vent
Max. glass thickness – vent
107 mm
88 mm
Min. glass thickness – frame/element
20 mm
Depth frame-vent
107 mm